beautypg.com

Grass Valley FIO-1901-RR User Manual

Page 24

background image

GUIDE TO INSTALLATION AND OPERATION

20 | FIO-1901-RR

ANNEX 1 – FIO-1901-RR User Interface (local menu structure)

STATUS

NO REAR, FIO-1901-RR-SRP, FIO-1901-TT-SRP, FIO-1901-RT-SRP, FIO-1901-R-SFP, FIO-1901-T-SRP

REAR MISMATCH

OPT.RxA

NO LOCK, NOSIGNAL, 270 Mbps, 1.5 Gbps, 3 Gbps

OPT.RxB

NO LOCK, NOSIGNAL, 270 Mbps, 1.5 Gbps, 3 Gbps

NO SFP, SFP-RR-LC, SFP-TT-S13S13-LC, SFP-RT-S13-LC, SFP-R-LC, SFP-T-S13-LC,
SFP-RR-W-LC,SFP-TT-C27C29-LC, SFP-TT-C31C33-LC, SFP-TT-C35C37-LC, SFP-TT-C39C41-LC,
SFP-TT-C43C45-LC, SFP-TT-C47C49-LC, SFP-TT-C51C53-LC, SFP-TT-C55C57-LC,
SFP-TT-C59C61-LC, SFP-TT-W13W15-LC

SFP MISMATCH

SFP VENDOR NAME (ex: GENNUM, OE ELECTRONICS,…)

SFP PART NUMBER (ex GO2920)

SFP REVISION

SFP TEMPERATURE (ex: [TEMP: LOW, NORMAL, HIGH])

SFP RECEIVE POWER A, (ex: RxA PWR: -15dBm, LOW, HIGH)

SFP RECEIVE POWER B, (ex: RxB PWR: -15dBm, LOW, HIGH)

FAIL OVER

MODE [OFF, ON]

FAIL DELAY

[0,…,3,…,14,15] seconds

OUTPUT CONFIG

ELE.OUT A

[OPTICAL RxA, OPTICAL RxB]

.

ELE.OUT B

[OPTICAL RxA, OPTICAL RxB]

RECLOCKER

OPTICAL RxA

[ON, BYPASS]

OPTICAL RxB

[ON, BYPASS]

USER PRESET

LOAD

[USER 1 ,USER 2, USER 3, USER 4, USER 5]

SAVE

[USER 1 ,USER 2, USER 3, USER 4, USER 5]

CONFIG ALARMS OPT.RxA NO LOCK

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxA NO SIGNAL ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxB NO LOCK

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxB NO SIGNAL ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxA PWR WARN ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxA PWR ERR.

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxB PWR WARN ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

OPT.RxB PWR ERR.

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

SFP TEMPERATURE

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

R./SFP MISMATCH

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

NO SFP

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]

ALARM

REPORT

[NONE, GPI]

VERSION

FIO-19RR: XXX

CPU BUILD: YYY

FACTORY DEFAULT RESTORE

Only if Fail Over mode is OFF

Only if matched SFP present

This item does not appear if the rear is matched to the card type

This item does not appear if the SFP is matched to the card type and rear

This manual is related to the following products: