3.3.4 The

Output & Optical panel


Manually configure the input-to-output connections. Each of
the two electrical outputs can be connected to either of the
two optical inputs. The default is A-to-A and B-to-B.

• When

Fail Over is ON, the configuration is fixed and

the settings made here are overridden. See section
3.3.5 below.
















3.3.5 The

Fail Over panel


When Failover mode is activated, the FIO-1901-RR is
configured with Optical In A as the source for both outputs,
and Optical In B as the backup. If Optical In A fails, the
outputs will be switched over to Optical In B (if it is valid),
after a defined delay. The delay can be set between 0 and
15 seconds, in order to accommodate deliberate or
anticipated breaks in the input data stream.

Mode:

Use the radio buttons to set the operating mode
to OFF or ON

Fail Delay: Use the slider to set the delay between the

detection of a failure on Optical In A and the
switchover to Optical In B (range is 0 to 15
seconds)


Note that turning this mode ON overrides the output
configuration set in the Output & Optical panel. See
section 3.3.4 above.





Figure 3.6 Output & Optical panel

Figure 3.7 Fail Over panel