Sonata Series — Planning and Installation Manual

59

Section

4

Troubleshooting

The Sonata AES-to-MADI converter has an integrated alarm system that
will alert the user of a power supply problem. There are three LEDs on the
front panel as well as an SMPTE standard alarm connector on the rear panel
for remote alarm monitoring. Internal regulated voltages are measured
along with the presence of each of the power supply voltages. Any internal
voltage error will turn the Alarm LED red.

LEDs

The Sonata converter power supplies are fully redundant and the unit can
operate using either supply. See

Table 20

for LED details.

Front Panel

Table 20. Front Panel LEDs

Signal Present LEDs

The AES-to-MADI and MADI-to-AES signal present LEDs will be off
unless a valid AES signal is being decoded, at which time the LED will then
be green. The Analog-to-MADI and MADI-to-Analog will be green when a
signal is present between -50 dB and -4 dB full-scale. The LED's will turn
red between -4 dBFS and 0 dBFS.

Display

Meaning

Power LEDs

Alarm

Green

Power on, OK

Red

Power on, at least one power fault A or B

Off

System is not powered

A

Green

Supply A on and OK

Red

Supply A bad or not plugged in

B

Green

Supply B on, and OK

Red

Supply B bad or not plugged in