displayed by the status LED on the card edge when an Overload alarm is set. Choices are:

• Green, Yellow, Red, Flashing Red

Max Level


This parameter is measured for the eight programs defined in the
Audio Programs panel, and uses the Momentary Loudness
values.

• Enable the alarm by selecting the checkbox.
• Select the Apply To All checkbox to apply the next alarm

settings modifications simultaneously to all eight programs.


The user sets the detection parameters for this error using three
sliders:

• Threshold (dBFS) – sets the signal level above which Max

Level will be considered to have been detected.

• Set Duration (sec) – sets the time interval over which Max

Level must be continuously detected before the error is
flagged.

• Clear Duration (sec) – sets the time interval over which a

non-Max-Level signal (i.e. below the Threshold) must be
continuously present to clear the alarm if it has been set.


Use the LED Color pulldown to choose the color that will be
displayed by the status LED on the card edge when a Max Level
alarm is set. Choices are:

• Green, Yellow, Red, Flashing Red

Min Level


This parameter is measured for the eight programs defined in the
Audio Programs panel, and uses the Momentary Loudness
values.

• Enable the alarm by selecting the checkbox.
• Select the Apply To All checkbox to apply the next alarm

settings modifications simultaneously to all eight programs.


The user sets the detection parameters for this error using three
sliders:

• Threshold (dBFS) – sets the signal level below which Min

Level will be considered to have been detected.

• Set Duration (sec) – sets the time interval over which Min

Level must be continuously detected before the error is
flagged.

• Clear Duration (sec) – sets the time interval over which a

non-Min-Level signal (i.e. above the Threshold) must be
continuously present to clear the alarm if it has been set.

Figure 5-19 Alarms – Audio – Max Level