3 the output panel, 4 the msb panel – Grass Valley ADC-1722 User Manual
Page 17

GUIDE TO INSTALLATION AND OPERATION
ADC-1722 | 17/22
Reference Used –
the text box names the reference currently in use.
3.4.3 The Output panel
Output Sample Rate – use the pulldown to select the sample rate
of the output digital audio
• Choices: 32, 48, 96 KHz
Word Length – use the pulldowns to select the digital audio word
length for the two outputs independently:
• Choices: 16, 18, 20, 24 bits
Origin – User-defined signal message (4 ASCII characters)
• Type the message in the box and [Enter] to insert it.
• The text will be red when typing, and black after entering
• To delete, click at the end of the message and backspace to
delete it, then [Enter}
Dest. – User-defined signal message (4 ASCII characters)
• Type the message in the box and [Enter] to insert it.
• The text will be red when typing, and black after entering
• To delete, click at the end of the message and backspace to
delete it, then [Enter}
3.4.4 The MSB panel
• Valid only for card Assy# 0696-1200-2xx.
• Feature not supported for card Assy# starting at 0696-
1200-400.
Channel – use the pulldown to select the audio information that
will be sent to the Densité frame’s optional Monitoring Switching
Bridge (MSB) card, if installed:
• Choices:
IN: L&R 1
IN: L&R 2
OUT: AES1
OUT: AES2