beautypg.com

Bed in, Table 1 – Grass Valley 8935CF User Manual

Page 27

background image

8935CF — Instruction Manual

27

Configuration and Monitoring

Table 1. Top Edge LED Names and Conditions

LED

Indication

Condition

FAULT

(red)

Off

Normal operation, module OK.

On continuously

Module has detected an internal fault.

Flashing

Configuration problems. Check inputs and settings. Missing video.

COMM

(yellow)

Off

No activity on frame communication bus.

Flashing

Locate Module command received by the module from a remote control system.

Pulse

(short duration

Activity present on the frame communication bus.

CONFIG

(yellow)

Off

Module is in normal operating mode, no configuration change in progress or initialization complete.

On continuously

Module is initiating or changing operating modes.

Flashing

Locate Module command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

REM OVR

(yellow)

Off

Not used in this application.

On continuously

SFP1

(bi-color

red/yellow)

Off

No SFP submodule is not installed in position 1 (top of module).

Yellow on

A supported SFP submodule is installed in position 1 (top of module). Normal operation.

Red flashing

An unsupported SFP submodule is installed in position 1 (top of module).

Red on

continuously

The SFP submodule in position 1 (top of module) has an internal fault.

SFP2

(bi-color

red/yellow)

Off

No SFP submodule is not installed in position 2 (bottom of module).

Yellow on

A supported SFP submodule is installed in position 2 (bottom of module). Normal operation.

Red flashing

An unsupported SFP submodule is installed in position 2 (bottom of module).

Red on

continuously

The SFP submodule in position 2 (bottom of module) has an internal fault.

This manual is related to the following products: