25

Configuration and Monitoring

With input reporting enabled, the input signal will be reported as Present
for all bit rates above 19Mb/s. Inputs not recognized by the module will be
reported as Not Monitored.

Local Configuration and Monitoring

The 8935CF module can be configured and monitored locally (from the
front edge of the circuit board) using the rotary and paddle switches and
the LEDs mounted on the top and bottom front edge of the module. LEDs
are used to indicate status of the signals and the current settings.

Onboard Controls

Local/Remote Jumper

The on-board jumper Local/Remote jumper, J8, (

Figure 16

) is set at the

factory for local and remote (LOC/REM position, pins 2-3) to allow remote
control. It can be changed to lock out remote control if desired (LOC posi-
tion, pins 1-2).

Rotary and Paddle Switches

Switch S1 and S2 on the front edge of the module are used for setting the
operating mode of each channel. Refer to

Local Mode Configuration on

page 31

for using these controls.

Figure 16. Local/Remote Jumper and Onboard Controls

8543_07