8900GEN-SM — Instruction Manual

39

8900GEN-SM Applications

Configure Primary Independent Reference (Slot 1)

1.

On the web page interface, locate the module in slot 1 and click on the
link to that module. The 8985FSP + GEN links are shown at left.

2.

Before beginning any type of configuration, select the link to the User
Settings web page and select the

Set Factory Defaults

button to recall

factory defaults to the host module and the 8900GEN-SM submodule.

3.

Connect the reference signal intended for use as the NTSC Primary
Frame Bus 1 reference to one of the Genlock Loop BNCs (J1 or J3) on the
host rear module in slot 1. Loop this signal to another location or
terminate in 75 ohms.

4.

Click on the Genlock web page link. This will bring up the Genlock web
page for the module in slot 1 (

Figure 16

).

Figure 16. Primary Genlock Web Page