Grass Valley 8900GEN-SM User Manual
Page 25
![background image](https://www.manualsdir.com/files/813201/content/doc025.png)
8900GEN-SM — Instruction Manual
25
8900GEN-SM Applications
5.
Set the following parameters on the Genlock web page under Genlock
Control:
•
Genlock –
Enabled
•
Input Selection Standard – set the pulldown frame rate to match the
reference input exactly if possible or set to one of the compatible
frame rates given in
.
Setting the pulldown to a frame rate that does not match the refer-
ence input exactly will produce a warning message as shown in
. The reference signal will still be locked as you
will note in the Genlock web page header. This is still a valid condi-
tion.
This warning message will also appear on the Status web page for
this host module as shown in
In arrow from the host module and the Status LED on the top of the
page will be yellow, indicating a warning condition exists. This will
not affect the Locked condition.
•
Loop Bandwidth –
Fast Lock
6.
Under Genlock Bus Timing, set all the timing controls (Line Offset,
Coarse Offset (37ns), and Fine Offset) to 0 (zero).
7.
Set the Drive Frame Reference Bus to
Auto
.
8.
On the Genlock web page, verify that the header reports the Status as
Locked
and the Output Bus as
Ref 1
.