Grass Valley 2010RDA-16 User Manual
Page 15
2010RDA-16 Instruction Manual
15
Power Up
A red FAULT LED indicates an error situation and, with the other LEDs,
can indicate the operational conditions presented in
. The table
describes signal output and LED indications for various input/reference
combinations and user settings.
Table 2. Indicator LEDs and Conditions Indicated
LED
Indication
Condition
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault.
Flashing
AES input missing or Mode Jumper not installed
COMM
(yellow)
Off
No activity on frame communication bus.
Long flash
Location Command received by the module from a remote control system.
Short flash
Activity present on the frame communication bus.
CONF
(yellow)
Off
Module is in normal operating mode.
On continuously
Module is initializing, changing operating modes or updating firmware. Simultaneous CONF
and FAULT LEDs on indicate FPGA load error.
Flashing
Indicates rate of change of paddle-controlled analog setting.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
LOCK 1
(green)
Off
Module does not detect a valid AES input signal on channel 1.
On continuously
Valid AES input signal is present on channel 1 and module is locked to it.
LOCK 2
(green)
Off
Module does not detect a valid AES input signal on channel 2 (dual mode only).
On continuously
Valid AES input signal is present on channel 2 and module is locked to it.