Telnetting to an oap module from a router, Telnetting to an oap module from a pc, Using a router as the ssh client – H3C Technologies H3C SR8800 User Manual
Page 8

2
After the configuration, you can log in to the operating system of the OAP module through the terminal
emulation program on the PC.
Telnetting to an OAP module through the network management
port
You can telnet to the operating system on an OAP module directly through the network management port
of the OAP module.
Telnetting to an OAP module from a router
1.
Assign an IP address to the network management port of the OAP module.
2.
Enable the Telnet server on the OAP v with the telnet server enable command.
3.
Connect one end of the cable to the Ethernet port of the router, and the other end to the network
management port of the OAP module.
4.
Make sure that the network management port of the router and that of the OAP module can reach
each other.
5.
Execute the telnet command on the router, with the IP address of the network management port of
the OAP module as the destination address. You can log in to the operating system of the OAP
module after a connection is established.
Telnetting to an OAP module from a PC
1.
Assign an IP address to the network management port of the OAP module.
2.
Enable the Telnet server on the OAP module with the telnet server enable command.
3.
Connect one end of the cable to the Ethernet port of the PC, and the other end to the network
management port of the OAP module.
4.
Make sure that the network management port of the PC and that of the OAP module can reach
each other.
5.
Execute the telnet command on the PC, with the IP address of the network management port of the
OAP module as the destination address. You can log in to the operating system of the OAP module
after a connection is established.
Logging in through the network management port of an OAP
module with SSH
You can use the SSH client to log in to the operating system of an OAP module through its network
management port.
Using a router as the SSH client
1.
Assign an IP address to the network management port of the OAP module.
2.
Enable the SSH server on the OAP module with the ssh server enable command.
3.
Connect one end of the cable to the Ethernet port of the router, and the other end to the network
management port of the OAP module.
4.
Make sure that the network management port of the router and that of the OAP module can reach
each other.