8
LED Color Status
Fault
description
Fault
LED
Red
Normal: Off
Abnormal:
On
The power module is shut down
for output over-voltage or
short-circuit protection, or has a
fan fault or some other faults.
CAUTION:
•
When the run LED is off, check whether an AC power input failure
occurs.
•
When the alarm LED is on, check whether an input over-voltage
or under-voltage, an output over-current, or an over-temperature
condition occurs.
•
When the fault LED is on, check whether an output over-voltage or
short-circuit condition or a fan fault occurs.
Output power distribution
Table 4 Output power distribution
Number
of
power
modules
Input
voltage
Max
output
power per
8-A output
Max output
power per
25-A
output
Total max
output power
of 8 outputs
1
220 VAC 448 W
1400 W
1600 W
110 VAC 448 W
800 W
800 W
2
220 VAC 448 W
1400 W
3200 W
110 VAC 448 W
1400 W
1600 W