Verifying the configuration – H3C Technologies H3C S12500 Series Switches User Manual
Page 46

38
# Enable SPBM both globally and on the provider network ports on the BCB. Assign the provider
network ports to B-VLAN 3001.
[BCB]spbm
[BCB-spbm]quit
[BCB]interface Ten-GigabitEthernet2/0/1
[BCB-Ten-GigabitEthernet2/0/1]port link-type trunk
[BCB-Ten-GigabitEthernet2/0/1]port trunk permit vlan 3001
[BCB-Ten-GigabitEthernet2/0/1]spbm enable
[BCB-Ten-GigabitEthernet2/0/1]quit
[BCB]interface Ten-GigabitEthernet2/0/2
[BCB-Ten-GigabitEthernet2/0/2]port link-type trunk
[BCB-Ten-GigabitEthernet2/0/2]port trunk permit vlan 3001
[BCB-Ten-GigabitEthernet2/0/2]spbm enable
[BCB-Ten-GigabitEthernet2/0/2]quit
[BCB]interface Ten-GigabitEthernet2/0/3
[BCB-Ten-GigabitEthernet2/0/3]port link-type trunk
[BCB-Ten-GigabitEthernet2/0/3]port trunk permit vlan 3001
[BCB-Ten-GigabitEthernet2/0/3]spbm enable
[BCB-Ten-GigabitEthernet2/0/3]quit
Verifying the configuration
Verify the configuration on BEBs (for example, BEB 1).
1.
Verify that the BEB has ISIS-SPB adjacency with its neighbor.
[BEB1] display spbm peer
Peer information for SPBM
-------------------------
System ID Port Circuit ID State Holdtime
0000.eeee.0101 XGE1/0/2 2 Up 29s
2.
Verify that the BEB has established tunnels to other BEBs.
[BEB1]display l2vpn vsi name test verbose
VSI Name: test
VSI Index : 0
VSI State : Up
MTU : 1500
Bandwidth : 102400 kbps
Broadcast Restrain : 5%
Multicast Restrain : -
Unknown Unicast Restrain: -
MAC Learning : Enabled
MAC Table Limit : Unlimited
Drop Unknown : -
SPB I-SID : 3001
SPB Connections:
BMAC BVLAN Link ID Type
0000-eeee-0141 3001 64 Unicast
0000-9999-0141 3001 65 Unicast
ACs:
AC Link ID State