beautypg.com

Verifying the configuration – H3C Technologies H3C S12500 Series Switches User Manual

Page 46

background image

38

# Enable SPBM both globally and on the provider network ports on the BCB. Assign the provider

network ports to B-VLAN 3001.

[BCB]spbm

[BCB-spbm]quit

[BCB]interface Ten-GigabitEthernet2/0/1

[BCB-Ten-GigabitEthernet2/0/1]port link-type trunk

[BCB-Ten-GigabitEthernet2/0/1]port trunk permit vlan 3001

[BCB-Ten-GigabitEthernet2/0/1]spbm enable

[BCB-Ten-GigabitEthernet2/0/1]quit

[BCB]interface Ten-GigabitEthernet2/0/2

[BCB-Ten-GigabitEthernet2/0/2]port link-type trunk

[BCB-Ten-GigabitEthernet2/0/2]port trunk permit vlan 3001

[BCB-Ten-GigabitEthernet2/0/2]spbm enable

[BCB-Ten-GigabitEthernet2/0/2]quit

[BCB]interface Ten-GigabitEthernet2/0/3

[BCB-Ten-GigabitEthernet2/0/3]port link-type trunk

[BCB-Ten-GigabitEthernet2/0/3]port trunk permit vlan 3001

[BCB-Ten-GigabitEthernet2/0/3]spbm enable

[BCB-Ten-GigabitEthernet2/0/3]quit

Verifying the configuration

Verify the configuration on BEBs (for example, BEB 1).

1.

Verify that the BEB has ISIS-SPB adjacency with its neighbor.

[BEB1] display spbm peer

Peer information for SPBM

-------------------------

System ID Port Circuit ID State Holdtime

0000.eeee.0101 XGE1/0/2 2 Up 29s

2.

Verify that the BEB has established tunnels to other BEBs.

[BEB1]display l2vpn vsi name test verbose

VSI Name: test

VSI Index : 0

VSI State : Up

MTU : 1500

Bandwidth : 102400 kbps

Broadcast Restrain : 5%

Multicast Restrain : -

Unknown Unicast Restrain: -

MAC Learning : Enabled

MAC Table Limit : Unlimited

Drop Unknown : -

SPB I-SID : 3001

SPB Connections:

BMAC BVLAN Link ID Type

0000-eeee-0141 3001 64 Unicast

0000-9999-0141 3001 65 Unicast

ACs:

AC Link ID State