ATL Telecom AM64/512 User Manual
Page 17
a
telecom
telecom
User Guide
User Guide
High Speed Modems
High Speed Modems
17
10.1 General
10.1 General
Scroll up and down through the items with the ñ and ò keys. Set the item to the required value using
the SELECT key. Program the entire set of configuration options by using the PROGRAM key.
A star appears by any item that has been changed but not programmed. The yellow program LED should
be lit when there are any items in the menu that have been changed but not programmed.
10.2 Menu Items
10.2 Menu Items
10.2.1 Master / Slave working
10.2.1 Master / Slave working
When two BBM’s are connected together to form a link, one must always be set to Master while, the
other has to be set to Slave. The transmission signal is different for a Master and Slave, so line
synchronisation will never be achieved if two like types (e.g. Master to Master) are connected together.
The Config Menu options are ;
The Master and Slave setting allows the Slave settings to be controlled by the Master, whereas, the Ind.
Master and Ind. Slave settings have to be manually configured at each end of a link. i.e.: They are
Independent of each other.
10.2.2 HDSL Pairs
10.2.2 HDSL Pairs
S
S
and on AM64/768 and AM64/1024 only
10.2.3 User Data Rate
10.2.3 User Data Rate
This is dependent on the speed of modem purchased from 64/384K up to 64/1024K.
SS
In steps of 64k
Note : If T/S Control Line operation is selected, the maximum data rate is not available (See 10.2.5).
10.2.4 Clock Source
10.2.4 Clock Source
When in Master mode the Config Menu display will show;
SS SS
1. The Internal mode sources the timing from the master unit’s own oscillator.
2. When the unit is operating in master mode the timing can be supplied from an external source.
3. The External mode accepts a clock at the bit or byte frequency.
When in slave mode the display will show (Note: This cannot be changed);
10.2.5 Control Line Operation
10.2.5 Control Line Operation
S S
S S
The Control settings determine how the interface control lines 105 and 109 (C & I for X.21) are passed
end to end across the link. There are three options as shown above, these are ;
Controls EOC
The line states are passed in reserved bits in the Embedded Operation Channel
Controls Off
The line states are not passed at all from one end to the other.
C> Ind. Master
C> Ind. Master
C> Slave Mode
C> Slave Mode
C> Internal Clk
C> Internal Clk
C> 1 Pair
C> 1 Pair
C> Ext Bit Clk
C> Ext Bit Clk
C> Rate = 64K
C> Rate = 64K
C> Ext Byte Clk
C> Ext Byte Clk
C> Rate = 128K
C> Rate = 128K
C> Controls Off
C> Controls Off
C> Rate = XXXX K
C> Rate = XXXX K
C> Controls EOC
C> Controls EOC
C> 2 Pairs
C> 2 Pairs
C> Line Clk
C> Line Clk
C> Ind. Slave
C> Ind. Slave
C> Master Mode
C> Master Mode
C> Controls T/S
C> Controls T/S