beautypg.com

ARAG SERIE 4663 Electric Control Box 7 - 9 User Manual

Page 13

background image

13

8

DIGITAL DISPLAY - PRESSURE DISPLAY

8.1 Notes

on

programming

After having modifi ed a parameter in the “OPT” advanced menu, to return to the main menu
turn the device OFF and then ON again.
When you are modifying a parameter or are in a menu other than the main menu and you do
not press a key within 10 seconds, the display will automatically return to the main menu.
When modifying a numerical value, keep the key pressed to enable quick-modifi cation.

8.2 Setting

before

use

8.2.1 “OPT”

advanced

menu

On control box installation, some settings are necessary for correct spraying
data display:

Unit of measure

To access the advanced menu keep the key pressed while switching ON the
device
until the “OPT” screen appears.

8.2.2 “UNIT”

unit

of

measure

The units of measurement for data display can be selected onto the control box display:

EU

= Europe (bar). [Predefi ned setting]

US

= USA (psi).

Access the “OPT” advanced menu as shown in par. 8.2.1.
1) The display alternatively fl ashes the set unit of measure and the word “UNIT”.
2) To modify the value, keep the keys pressed simultaneously until the “SET” screen appears.
3) Press to select the unit of measure you wish to use.
4) To confi rm the setting, keep the keys pressed simultaneously until the “SAVE” screen appears.
The display alternatively fl ashes the set unit of measure and the word “UNIT”.