6.2.5 Sensor

connections

Fasten connectors according to the abbreviations indicated in the main assembly diagram
(par. 4.3).

The cables are marked to indicate the service to which they connect.
Table 1 gives full indications for the connections.

The sensor connection instructions are provided with the respective products.
Connect the fl ow meter or transducer connector with the correct polarity; insert in the correct way
and push in until the tab clicks.

Fig. 7

Use ONLY the accessories listed in the catalogue; these have the correct
specifi cations for their intended application.

6.2.6 Power

connection

CAUTION: Before powering up the control box and control unit, make sure the bat-
tery voltage is as specifi ed (12 Vdc).

Power up the control box with the starter key, using the provided power cable
(component 5 - Tab. 1).

If the 15/54 contact (services) of the start key can bear a continuous load of 10A, install the
connections indicated in Fig. 8, with a 10A fuse on the power cable.
Otherwise install a relay as indicated in Fig. 9, and install a 10 A fuse on the power cable.
Use cables whose section is a minimum of 2.5 mm

2

.

Direct connection

Fig. 8

Connection via relay

Fig. 9

CAUTION:
• To avoid short circuits, do not connect the power cable before the installation is
completed.
• Use cables with suitable terminals to ensure correct connection of each individual
wire.