Plumbing Instructions
1.
Using a quality thread sealing compound install line fittings into each lifting cylinder taking into
consideration hose routing for fitting direction and placement.
2.
Follow the next installation steps using Figure #2 as a reference.
3.
Cut tubing to desired length with a razor blade or similar tool to prevent crushing or distorting
tubing. Tubing should be cut off square to ensure proper installation and sealing.
4.
Install brass sleeve inside tubing until flush with end of tubing.
5.
Slide nut with captive sleeve over tubing.
6.
Tighten the nut with captive sleeve, finger tight onto fitting body while inserting tubing until
it bottoms in the fitting.
7.
Complete the seal with one to two turns of the nut with a wrench.
Air Lance Receiver Position
Position the air lance receiver so that it remains protected from damage, and
debris that may enter the air system. Also take into consideration comfort and
ease of access for plugging in the air lance.
Initial Regulator Set-Up
Before lifting vehicle for the first time the regulator must be calibrated for the weight of the vehicle. Once
the entire system is plumbed, the regulator for the nitrogen must be set. Begin calibrating regulator by set-
ting regulator pressure to approximately 200 psi. Follow lifting instructions, gradually increasing regulator
pressure until vehicle is fully raised and safety stands can be installed (See Figure #3). Do not exceed 400psi.