Westermo RM-505U-2-E User Manual
Page 42
![background image](https://www.manualsdir.com/files/809683/content/doc042.png)
505U Radio Telemetry Module
Page 42
© September 2002
Current Drain
120
µ
A
10mA + analogue loop
current
“Sleep” mode
Operating mode
Analogue loop supply
Included
10 - 12V DC 50mA
Low Battery voltage status
Monitored
Can be transmitted to remote
modules
Radio Transmitter
Frequency
405 - 490 Mhz
12.5/20 kHz channel spacing
Synthesised Transmitter -
Frequency configurable range
10MHz
Direct frequency modulation
Transmit power
10, 100, 500mW
250mW max. with internal
batteries (500mW with 3dB
antenna), 100mW max with 2 x AA
internal battery supply
Spurious emissions
TX - <-37 dBm
Frequency Stability
+/- 1.0 kHz
Expected line-of-sight range
2 km @ 10mW EIRP
5 km @ 100mW EIRP
10 km @ 500 mW EIRP
Range may be extended by using up
to 5 intermediate 105U modules as
repeaters,
Antenna Connector
Female BNC coaxial
Serial Ports
RS232 Port
DB9 female DCE
4800 baud, no parity, 8 data bits, 1
stop bit
Data transmission
- digital inputs
On change-of-state + after
update period elapsed
Update time configurable 10 secs -
5 days. Separate, faster update time
may be configured when input is
ON
Data transmission
- pulse inputs
Transmitted as pulse count
Transmitted when count change
exceeds configured amount, or on
time elapsed since last transmission
(configurable 10 secs - 5 days)
2 pulse inputs may be
configured to a single count
Suitable for quadrature or
incremental shaft encoders.