Type tests and environmental conditions – Westermo GDW-11 User Manual
Page 12
12
6615-2203
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
± 6 kV
Enclosure air
± 8 kV
RF field AM
modulated
IEC 61000-4-3
Enclosure
20 V/m 80% AM (1 kHz), 80 – 2000 MHz
RF field 900 MHz
ENV 50204
Enclosure
20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
Fast transient
EN 61000-4-4
Signal ports
± 2 kV
Power ports
± 2 kV
Surge
EN 61000-4-5
Signal ports unbalanced
± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced
± 2 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 230 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 230 MHz
Power frequency
magnetic field
EN 61000-4-8
Enclosure
100 A/m, 50 Hz, 16.7 Hz & 0 Hz
Pulse magnetic field
EN 61000-4-9
Enclosure
1000 A/m, 6.4 / 16 ms 5 pos/5neg pulse in XYZ
direction
Voltage dips and inter-
ruption
EN 61000-4-11
AC power ports
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
Mains freq. 50 Hz
EN 61000-4-16
Signal ports
100 V 50 Hz line to earth
Mains freq. 50 Hz
SS 436 15 03
Signal ports
250 V 50 Hz line to line
Voltage dips
and interruption
EN 61000-4-29
DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class B
FCC part 15
Class B
Conducted emission
EN 55022
AC power ports
Class B
FCC part 15
AC power ports
Class B
EN 55022
DC power ports
Class B
Dielectric strength
EN 60950
Signal port to other
isolated ports
2 kVrms 50 Hz 1 min
Power port to other
isolated ports
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)
Any port to any port
and enclosure
0,5 kVrms 50 Hz 1 min (GDW-11 EX)
Environmental
Temperature
Operating
–25 to +50°C
Storage & Transport
–30 to +85°C
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 year
Vibration
IEC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
Shock
IEC 60068-2-27
Operating
15 g, 11 ms
Packaging
Enclosure, GDW-11
UL 94
PC / ABS
Flammability class V-1
Enclosure, EX-versions
Cabelec 6141
Dimension W x H x D
35 x 121 x 119 mm
Weight
0.2 kg
Degree of protection
IEC 529
Enclosure
IP 21
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail