beautypg.com

Type tests and environmental conditions – Westermo GDW-11 User Manual

Page 12

background image

12

6615-2203

Type tests and environmental conditions

Electromagnetic Compatibility
Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 6 kV

Enclosure air

± 8 kV

RF field AM
modulated

IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz), 80 – 2000 MHz

RF field 900 MHz

ENV 50204

Enclosure

20 V/m pulse modulated 200 Hz, 900 ± 5 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports unbalanced

± 2 kV line to earth, ± 2 kV line to line

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 230 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 230 MHz

Power frequency
magnetic field

EN 61000-4-8

Enclosure

100 A/m, 50 Hz, 16.7 Hz & 0 Hz

Pulse magnetic field

EN 61000-4-9

Enclosure

1000 A/m, 6.4 / 16 ms 5 pos/5neg pulse in XYZ
direction

Voltage dips and inter-
ruption

EN 61000-4-11

AC power ports

10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Voltage dips
and interruption

EN 61000-4-29

DC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

Radiated emission

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Dielectric strength

EN 60950

Signal port to other
isolated ports

2 kVrms 50 Hz 1 min

Power port to other
isolated ports

3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)

Any port to any port
and enclosure

0,5 kVrms 50 Hz 1 min (GDW-11 EX)

Environmental
Temperature

Operating

–25 to +50°C

Storage & Transport

–30 to +85°C

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging
Enclosure, GDW-11

UL 94

PC / ABS

Flammability class V-1

Enclosure, EX-versions

Cabelec 6141

Dimension W x H x D

35 x 121 x 119 mm

Weight

0.2 kg

Degree of protection

IEC 529

Enclosure

IP 21

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail