Step 3:

If you would like to use SNTP to sync time with a SNTP

V4 Server, click Time Sync button to setup it as figure
2.3-4.

Figure 2.3-4

Parameter Description:

SNTP Server: This is the list of server names. The names

may be separated with semicolons, commas, or spaces.

Polling Interval (second): If startup sync is false, try to set the

time each time this many seconds elapses.

Min Retry Interval (second): This is the initial retry interval.

NTP client will always wait at least this long between retry
attempts when there are errors.

Max Retry Interval (second): This is the max time NTP client

will ever wait before attempting a retry when there have been
errors.

Max Adjust Time (second): If this is zero, NTP client will be

willing to apply any size time adjustment. If this is non-zero,
then any time adjustment greater than this will be considered
an error.

NTP Server Port: This is the port number NTP client will at-

tempt to connect to on the time server. The default value is
123.

Local NTP Port: This is the port number NTP client will use to

listen for replies from the server. The default value of 0
means use a random port number.

Packet Error Check: Enable to validate the contents of the

incoming replies from NTP sever or not.

If you need to check the SNTP log, please use Get Log button to
review the NTP time log (advance user only).