beautypg.com

Configuration option 3: click supervisor, Install click supervisor, Make a connection – Wavetronix Click 112 (detector rack card) (CLK-112) - Quick-reference Guide User Manual

Page 4: Select a driver, Configure the module

background image

WX-500-0177

© 2014 Wavetronix LLC. All rights reserved. Protected by US Pat. Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,889,098; 7,924,170; 7,991,542; 8,248,272;

8,665,113; and Cdn. Pat. Nos. 2,461,411; 2,434,756; 2,512,689; and Euro. Pat. Nos. 1435036; 1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click,

Command and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective hold-

ers. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.

6

Configuration option 3: Click Supervisor

Install Click Supervisor

Click Supervisor is the third available way to configure the Click 112/114. To

install it:
1 Download the setup file from www.wavetronix.com (under Support).

2 Double-click on the file to run the setup wizard. Follow the steps to install.

Make a connection

1 Make sure there is a connection between the Click 112/114 and the com-

puter that Click Supervisor is on. To do this, there should be a jumper cable

connected from the bus 2 port to a Click device with an RJ-11 jack on the

T-bus, such as a Click 222.

2 Run Click Supervisor and select Communication. This screen lets you pick the type of connection you

want to make, serial or IP. The Click 112/114 will likely be configured using serial communication.

3 Click Settings to make any necessary changes to the settings, such as the port or the baud rate. Click

OK to return to the Communication screen, then click Connect. Keep the Click ID set to 0.

4 In the next screen, Click Supervisor will display all the devices it discovers. When the desired Click

112/114 appears, select it and click Select. Click Supervisor will connect to the device.

Select a driver

Select Setup Click on the main screen. In the next

screen, select the Expert driver and click OK.

Configure the module

The System > General tab has text parameters that

cannot be changed anywhere else. The most important

of these include:

˽

Description/Location – For informational/iden-

tification purposes only. These settings do not

affect the operation of the device.

˽

Device ID – Changes the ID number associated with the device. By default this is the last five digits of the

serial number. The System > Settings tab lets you set certain parameters that can also be changed using the

front panel menu and the DIP switches.

˽

Baud Rate for Bus 1/2 – Changes the baud rates of buses 1 and 2.

˽

Input Mapping – Lets you map two or four of the input data channels coming from the sensor to the

output channels on the device. The outputs are assigned sequentially, so if you select 13–14, then input

13 will be mapped to channel 1, and 14 to channel 2.

Note. If any of the DIP switches are turned on, that parameter will be in Hardware mode and Click Supervi-

sor will only be able to display, not change, that setting.