Select configuration method
4
Configuration option 1: DIP switches
The DIP switches on the circuit board can be used to change input mapping and the baud rates used for bus
1 and bus 2. These parameters can also be changed using the two other configuration options.
Note. For each parameter, if any of the switches are turned on, that parameter is in Hardware mode. If
Hardware mode is selected, the parameter can only be configured using the switches.
Look at the figure below to see how to set the switches in order to configure the parameter. To turn a switch
on, flip it up.
Channel Input Mapping
This function lets you map two (Click
112) or four (Click 114) of the input data
channels coming from the sensor to the
output channels on the device. The out-
puts are assigned sequentially, so if you se-
lect 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
This function lets you set the baud rate for bus 1 and bus 2. The two buses can be configured separately. Flip
the switches up and down according to the diagram to set the baud rate for each bus.
The Click 112/114 can be configured in three ways: DIP switches, the front panel menu and Click Super-
visor. These three different configuration methods can configure different sets of options; some of these
parameters can be set using multiple configuration methods, and some of them can only be set using one
particular method. This table lists how each
parameter may be accessed and configured.
The final row on the table refers to configu-
ration modes. The DIP switches are used
to choose between Hardware and Software
modes. If any of the switches are on, that
particular parameter is set to Hardware
mode and only the DIP switches can be used
to change its configuration options. If no
switches are on for a particular parameter,
it is in Software mode and the front panel
menu and Click Supervisor must be used to
configure it.
DIP Switch Front Panel
Menu
Click
Supervisor
Baud Rate
Yes
Yes
Yes
Channel Input Map
Yes
Yes
Yes
Autobaud
No
Yes
No
Reset to Default
No
Yes
Yes
Description
No
No
Yes
Location
No
No
Yes
Device ID
No
No
Yes
To use this
configuration method:
Hardware
Mode
Software
Mode
Software
Mode