Select configuration method

4

Configuration option 1: DIP switches

The DIP switches on the circuit board can be used to change input mapping and the baud rates used for bus

1 and bus 2. These parameters can also be changed using the two other configuration options.

Note. For each parameter, if any of the switches are turned on, that parameter is in Hardware mode. If

Hardware mode is selected, the parameter can only be configured using the switches.

Look at the figure below to see how to set the switches in order to configure the parameter. To turn a switch

on, flip it up.

Channel Input Mapping

This function lets you map two (Click

112) or four (Click 114) of the input data

channels coming from the sensor to the

output channels on the device. The out-

puts are assigned sequentially, so if you se-

lect 13–14, then input 13 will be mapped

to channel 1, and 14 to channel 2.

Baud Rate for Bus 1 and Bus 2

This function lets you set the baud rate for bus 1 and bus 2. The two buses can be configured separately. Flip

the switches up and down according to the diagram to set the baud rate for each bus.

The Click 112/114 can be configured in three ways: DIP switches, the front panel menu and Click Super-

visor. These three different configuration methods can configure different sets of options; some of these

parameters can be set using multiple configuration methods, and some of them can only be set using one

particular method. This table lists how each

parameter may be accessed and configured.
The final row on the table refers to configu-

ration modes. The DIP switches are used

to choose between Hardware and Software

modes. If any of the switches are on, that

particular parameter is set to Hardware

mode and only the DIP switches can be used

to change its configuration options. If no

switches are on for a particular parameter,

it is in Software mode and the front panel

menu and Click Supervisor must be used to

configure it.

DIP Switch Front Panel

Menu

Click

Supervisor

Baud Rate

Yes

Yes

Yes

Channel Input Map

Yes

Yes

Yes

Autobaud

No

Yes

No

Reset to Default

No

Yes

Yes

Description

No

No

Yes

Location

No

No

Yes

Device ID

No

No

Yes

To use this

configuration method:

Hardware

Mode

Software

Mode

Software

Mode