Configuration option 2: front panel menu – Wavetronix Click 112 (detector rack card) (CLK-112) - Quick-reference Guide User Manual
Page 3
5
Configuration option 2: front panel menu
The front panel menu allows you to configure input mapping and baud rates. It can also reset the device to
factory defaults, and is the only place on the device to access the autobaud function.
Menu and configuration options are displayed on the Level 1 and Level 2 LEDs on the faceplate. Navigate
through the menu using the mode switch:
1 Press and hold the mode switch to enter Menu mode. The Level 1 LEDs will start to light up to indicate
that the device is cycling through all menu options.
2 When the LEDs light up in the way that indicates the menu option you want (see the figure below),
release the mode switch.
3 Quickly press and release the mode switch to select the current menu option. The Level 2 LEDs will
light up to let you configure the options for the selected menu option.
4 Press and hold the mode switch to cycle through available values for the selected menu option. The
Level 2 LEDs display the currently selected value.
5 Press and release the mode switch to accept the displayed value. The device will exit the menu.
Note. If any of the DIP switches are turned on, that parameter will be in Hardware mode and the front
panel menu will only be able to display, not change, that setting.
See the figure to the right for how to use the LEDs to configure the parameter.
Channel Input Mapping
This function lets you map two (Click
112) or four (Click 114) of the input
data channels coming from the sensor to
the output channels on the device. The
outputs are assigned sequentially, so if you
select 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
This function lets you set the baud rate
for bus 1 and bus 2. The two buses can
be configured separately.
Autobaud
This function initiates an autobaud on the RS-485 bus you select. If the autobaud is successful, the LEDs will
display the baud rate found, using the same LED patterns used for the baud rate (see figure above). If it fails,
all four LEDs will flash, and then the device will exit the menu.
Reset to Default
This function will restore all configuration settings to factory defaults (even those not configured using the
front panel menu): baud rate, channel map, description field, location field and device ID.