beautypg.com

Watson-Marlow 505Di User Manual

Page 31

background image

31

English

N2. Dose program called for use
O2. Indication of dosing time interval and pump speed
P2. Volume/weight set and number of doses. Press start
Q2. Pump starts dosing run
R2. Option to restart dosing, re-calibrate pump or exit from dosing
S2. Restart dosing
T2. Decision to re-calibrate pump
U2. Prompt to enter volume which pump is physically dosing during each shot
V2. Measure and then enter manually the actual volume/weight which has been dosed
W2. Default tolerance limit of +/-25% of pre-set dose volume on actual dosing volume entered
X2. Decision to exit from dose program
Y2. The dosing batch is paused. Option to restart or stop
Z2. Decision to re-start dosing
A3. Decision to stop dosing
B3. Indication of volume/weight dosed and number of doses completed
C3. Option to restart dosing or return to Main menu
D3. Return to Main menu
E3. Unsaved dose settings will be called
F3. Saved dose setting will be called
G3. Indication of dose program which has been called
H3. Dosing time interval and start prompt