Chapter 3 - Handling of Control Panel CDP 31x
DCS 500B / DCP 500B Operating Instructions
IV A
3 - 7
3.5 Saving of the Parameters to backup memory
Step
Function
Press key
Display after key is
pressed
1.
To enter the Parameter Mode
Selection
PAR
0 L 0.0 rpm 00
2 ANALOG OUTPUTS
05 AO2.[IN]
105.01
2.
Select group 112.
While holding the arrow down,
only the group name is dis-
played. When the key is re-
leased, number, name and
value of the first parameter in
the group is displayed.
0 L 0.0 rpm 00
112 MAINTENANCE
0 L 0.0 rpm 00
112 MAINTENANCE
01 COMMIS STAT
NOT ACTIVATED
3.
Select signal number 02 from
group 112.
While holding the arrow down,
only the signal name and num-
ber are displayed. When the key
is released the value is also dis-
played.
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
NONE
4.
Press ENTER to select
BACKUPSTOREMODE.
ENTER
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
[NONE]
5.
Saving of changed values.
Select Set1 (SAVE MOT1 SET)
or Set2 (SAVE MOT2 SET).
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
[SAVE MOT1 SET]
6a.
6b.
Confirmation of the saving.
Saving procedure is completed
when NONE is displayed.
To cancel the saving and keep
the original value press any key
before pressing
ENTER
.
The selected Keypad Mode is
entered.
ENTER
ACT
PAR
FUNC
DRIVE
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
ERASING...
0 L 0.0 rpm 00
112 MAINTENANCE
02 BACKUPSTOREMODE
NONE