Iv a, Only if analog tacho is used as speed feedback, Switch off power, thus stopping the drive – DCS 500 User Manual

Page 31: Caution! please don't forget, Chapter 2 - start-up instructions

background image

Chapter 2 - Start-Up Instructions

DCS 500B / DCP 500B Operating Instructions

IV A

2 - 19

Only if analog tacho is used as speed feedback!

Switch ON power; start drive.

DANGER: System components now energized!

12516 = increase slowly up to 20000 (=100 % speed).

Check motor voltage; if value has been set with 501, motor voltage must
remain constant, or must not exceed this value.

Measure speed with manual tacho; balance maximum speed with R9, R48 or
R2716.

12516 = 0

Switch OFF power, thus stopping the drive!

CAUTION! Please don't forget!

11202 = SAVE MOT1 SET

Save the altered values in the non-volatile memory!

3ADW000055R0401_DCS500B_Operating Instruction_e_d