SNMP Agent C-5
PRISM 4151
ddsDteNoAlarm(1) - DTE interface has no current
alarms
ddsDteDtrAlarm(2) - DTE interface has currently
declared a loss of DTR alarm
ddsDteInterfaceType: (read- only)
Reports the DTE interface type being used
ddsDteInterfaceV35(1) - DTE interface is a V.35
ddsDteInterface232(2) - DTE interface is a RS232
ddsDteInterfaceOther(3) - DTE interface is something
other than listed above
ddsDteInterfaceNotAvail(4) - DTE interface type is not
available
ddsDteV54Loop: (read- write)
Allows you to select or verify the operational state of the
V.54 option
ddsDteV54LoopEnabled(1) - The unit will currently
respond to V.54 loop codes
ddsDteV54LoopDisabled(2) - The unit will not respond
to V.54 loop codes
ddsDteRtsCtsDelay: (read- write)
Allows you to verify or select the delay used in the transi-
tion time on RTS and CTS. For the PRISM 4151, only the
ddsDteRtsCtsDelayNormal and ddsDteRtsCtsDelayLong
option are valid.
ddsDteRtsCtsDelayOff(1) - Delay is turned off
ddsDteRtsCtsDelayNormal(2) - Delay is a normal
amount based on the data rate and the hardware
ddsDteRtsCtsDelayLong(3) - Delay is generally doubled
from the normal delay
ddsDteRtsCTSDelayUserDefined(30) - Delay has been
user defined to some other value, when this value is set
the delay is set to 30ms
ddsDteRtsStatus: (read- only)
Reports the current status of the RTS control lead
ddsDteRtsStatusHigh(1) - RTS control lead is in the
active HIGH state
ddsDteRtsStatusLow(2) - RTS control lead is in the
active LOW state
ddsDteCtsStatus: (read- only)
Reports the current status of the CTS control lead
ddsDteCtsStatusHigh(1) - CTS control lead is in the
active HIGH state
ddsDteCtsStatusLow(2) - CTS control lead is in the
active LOW state
ddsDteDcdStatus: (read- only)
Reports the current status of the DCD control lead
ddsDteDcdStatusHigh(1) - DCD control lead is in the
active HIGH state
ddsDteDcdStatusLow(2) - DCD control lead is in the
active LOW state
ddsDteDtrStatus: (read - only)
Reports the current status of the DTR control lead
ddsDteDtrStatusHigh(1) - DTR control lead is in the
active HIGH state
ddsDteDtrStatusLow(2) - DTR control lead is in the
active LOW state
ddsDteDsrStatus: (read- only)
Reports the current status of the DSR control lead
ddsDteDsrStatusHigh(1) - DSR control lead is in the
active HIGH state
ddsDteDsrStatusLow(2) - DSR control lead is in the
active LOW state
ddsDteDsrControl: (read-write)
Allows you to review and configure the DTE DSR lead (Cir-
cuit 107/CC)
ddsDteDsrControlTestOff(1) - DSR is on except when
the unit is in test
ddsDteDsrControlForcedOn(2) - DSR is on regardless
of any unit condition
ddsDteDcdControl: (read-write)
Allows you to review and configure the DTE DCD lead
(Circuit 109/CF).
ddsDteDcdControlIdleOff(1) - DCD is on except when
the unit is receiving Idle Code from the network.
ddsDteDcdControlForcedOn(2) - DCD is on regardless
of any unit condition
ddsDteRtsControl: (read-write)
Allows you to review or configure the DTE RTS and CTS
leads (Circuit 105/CA and 106/CB).
ddsDteRtsControlNormal(1) - RTS, Circuit Assurance,
and Antistreaming control CTS
ddsDteRtsControlForcedOn(2) - RTS is ignored, CTS is
on regardless of any unit condition
ddsDteDtrAlarm: (read-write)
Allows you to enable or disable monitoring on the DTR lead
(Circuit 108/CD).
ddsDteDtrAlarmEnabled(1) - DTR low is an alarm con-
dition
ddsDteDtrAlarmDisabled(2) - DTR is ignored
ddsDteRLDetect: (read-write)
Allows you to override the DTE RL input pin on the
Remote Loopback lead (Circuit 140/RLB)
ddsDteRLDetectEnabled(1) - RLB high activates the
Remote V.54 Loop
ddsDteRLDetectDisabled(2) - RLB is ignored
ddsDteLLDetect: (read-write)