C-4 SNMP Agent
PRISM 4151
ddsNetAntiStrTimerOff(1) - AntiStreaming Timer is off
ddsNetAntiStrTimer10(2)
-
AntiStreaming Timer is
set to 10 seconds
ddsNetAntiStrTimer30(3)
-
AntiStreaming Timer is
set to 30 seconds
ddsNetAntiStrTimer60(4)
-
AntiStreaming Timer is
set to 60 seconds
ddsNetLoopMode: (read-write)
Allows you to review or set Loop Mode to unidirectional or
bidirectional
ddsNetLoopModeUnidirectional(1) - Line, Data, and
V54 loops will be unidirectional Local loop will be bidi-
rectional
ddsNetLoopModeBidirectional(2) - All loops will be
bidirectional
DDS DTE Objects
ddsDteRate: (read-write)
Allows you to verify or select the DDS DTE data rate. Only
the ddsDteRate56000 and ddsDteRate64000 apply to the
PRISM 4151. Both rates are controlled by the ddsNetMode
setting and cannot be changed independently.
ddsDteRate2400 - 2400bps
ddsDteRate4800 - 4800bps
ddsDteRate9600 - 9600bps
ddsDteRate19200 - 19200bps
ddsDteRate38400 - 38400bps
ddsDteRate54000 - 54000bps
ddsDteRate56000 - 56000bps
ddsDteRate57600 - 57600bps
ddsDteRate62000 - 62000bps
ddsDteRate64000 - 64000bps
ddsDteFormat (read-write)
This variable describes the current operations format of the
DTE interface. Only the ddsDteFormatSync applies to the
PRISM 4151.
ddsDteFormatSync(1) - DTE interface is currently set to
operate in Synchronous clocking format
ddsDteFormatAsync(2) - DTE interface is currently set
to operate in the Asynchronous clocking format
ddsDteFormatNotAvail(3) - DTE interface operating
format is not available
ddsDteParity: (read- write)
Allows you to verify or select parity for the DTE interface.
This variable is only valid when the DTE Mode is set to
ASYNC. For the PRISM 4151, the value always returns
ddsDteParityNotAvail. This value cannot be modified.
ddsDteParityNone(1) - DTE interface is currently set for
no parity bit checking or generation
ddsDteParityOdd(2) - DTE interface is currently set for
odd parity
ddsDteParityEven(3) - DTE interface is currently set for
even parity
ddsDteParityMark(4) - DTE interface is currently set for
mark parity
ddsDteParitySpace(5) - DTE interface is currently set
for space parity
ddsDteParityNotAvail(6) - Parity setting on the DTE
interface is not available.
ddsDteStopBit: (read- write)
Allows you to verify or set the stop bit setting for the DTE
interface. This variable is only valid when the DTE interface
is set to ASYNC. For the PRISM 4151, the value always
returns ddsDteStopBitNotAvail. This value cannot be modi-
fied.
ddsDteStopBit1(1) - DTE interface is configured to oper-
ate in the ASYNC mode with 1 stop bit
ddsDteStopBit2(2) - DTE interface is configured to oper-
ate in the ASYNC mode with 2 stop bits
ddsDteStopBitNotAvail(3) - Stop bit information is not
available. The DTE interface is probably configured for
synchronous operation.
ddsDteSendCode: (read - write)
Allows you to start or verify the setting of the DTE BERT.
This variable describes what type of test code is being sent
from the DDS unit back towards the DTE. For the PRISM
4151, only the ddsDteSendNoCode applies. Other values are
accepted but not acted upon.
ddsDteSendNoCode(1) - Normal data mode of operation
ddsDteSendOtherPattern(2) - Sending some other stress
pattern than 511
ddsDteSend511Pattern(3) - Sending 511 stress pattern
toward the DTE
ddsDteLoopConfig: (read- write)
Allows you to set a DTE loop or verify the status of a DTE
loop
ddsDteNoLoop(1) - Normal data mode of operation
ddsDteV54Loop(2) - Data is looped back toward the
DDS network and toward the DTE loop activated via
V.54 loop codes
ddsDteDataLoop(3) - Data is looped back toward the
DTE loop activated via data loop code received from
the network
ddsDteOtherLoop(4) - DTE interface has some loop
other than one of the above listed loops active
ddsDteFarEndV54Loop(5) - The far end unit has a V.54
loop current on it's DTE interface
ddsDteStatus: (read- only)
Reports the current operations status of the DTE interface