Diagnostics

5-4

Verilink NCC 2130 User Manual

Table 5-1

Diagnostic Menu Status Messages

Diagnostic

Commands

There are twelve command options available on the NCC 2130
Diagnostics Menu.

Table 5-2

lists all of these commands in right

to left order:

Drawings illustrating the various loopbacks can be found in the
manual

AS2000, The Basics

.

Message

Meaning

ALARM

Yellow Alarm (RAI) —The CSU is receiving a Remote Alarm Indication Signal on the

port. This signal is sent by a device in a red alarm condition, such as AIS, LOS or LOF.

FRAME LOSS

Out Of Frame (OOF) —The CSU does not detect a valid framed signal on the port. If

pulses are also present. Can indicate receipt of unframed all ones—Alarm Indication

Signal (AIS)—which is often used as a Keep Alive signal on T1 circuits.

SIGNAL LOSS

Loss Of Signal (LOS) —The CSU does not detect any pulses on the port. This is the

worst possible alarm condition on a T1 port. Ignore other alarms and resolve the

cause of the LOS first. In the case of a DTE port reporting LOS, it means the LOS

option is configured to expect RTS or DTR from the DTE and that signal is not

present.

CRC ERRORS

Cyclic Redundancy Check errors (CRC-6) —the CSU detects errors using the CRC-6

feature of ESF framing. Applies only to T1 circuits using ESF framing.

BPV

The CSU is detecting bipolar violations on the port. Two or more pulses in a row were

of the same polarity, violating the Alternating Mark Inversion requirement.

EXT CLK LOSS

The CSU is configured to use an external clock signal and that signal is not detected.

PULSES

Not an alarm condition. The CSU does see valid pulses on the port. PULSES should

always be displayed on the DTE side of the menu.