Verilink NCC 2130 (880-503285-001) Product Manual User Manual
Page 34

Configuration
3-16
Verilink NCC 2130 User Manual
83
NCC 2130
TAC 2130
DIU 2130
DSU canned configuration #3, assigns timeslots 1-8 to data port #1
and timeslots 9-16 to data port #2 (data port #2 ignored by TAC/NCC
2130).
84
NCC 2130
TAC 2130
DIU 2130
DSU canned configuration #4, assigns timeslots 1-6 to data port #1
and timeslots 7-12 to data port #2 (data port #2 ignored by TAC/NCC
2130).
85
NCC 2130
TAC 2130
DIU 2130
DSU canned configuration #5, assigns timeslots 1-4 to data port #1
and timeslots 5-8 to data port #2 (data port #2 ignored by TAC/NCC
2130).
86
NCC 2130
TAC 2130
DIU 2130
DSU canned configuration #6, assigns timeslots 1-2 to data port #1
and timeslots 3-4 to data port #2 (data port #2 ignored by TAC/NCC
2130).
87
NCC 2130
TAC 2130
DIU 2130
DSU canned configuration #7, assigns timeslots 1-23 to data port #1
and timeslot 24 to data port #2 (data port #2 ignored by TAC/NCC
2130).
88
NCC 2130
TAC 2130
DIU 2130
DIU 2131
Sets DTE port(s) clock to TT , data port samples Transmit Data during
negative going transition of clock received from DTE (on the pair
Terminal Timing in RS-422, SCTE in V.35 or XTC in RS-232).
89
NCC 2130
TAC 2130
DIU 2130
DIU 2131
Sets DTE port(s) clock to inverted ST (ST) data port samples Transmit
Data lead during positive going transition of transmit clock signal.
90
NCC 2130
TAC 2130
DIU 2130
DIU 2131
Sets DTE ports to n
×
56 kbit/s (as required for an AMI T1).
91
NCC 2130
TAC 2130
DIU 2130
DIU 2131
Unassigns Port 1 timeslot(s).
92
DIU 2130
Unassigns Port 2 timeslot(s).
99
NCC 2130
Resets NCC password for Craft interface to default condition of no
password. (use only with 31, as in 31/99).
00
ALL
Clears the address command, releases currently selected module. Use
this command if you change your mind after selecting a module in
step two, or if you select the wrong module accidentally, or to practice
double-clicking.
Code
Applies to
Description