The configuration menu, The configuration menu -3 – Verilink NCC 2130 (880-503285-001) Product Manual User Manual
Page 21

Configuration
Verilink NCC 2130 User Manual
3-3
Table 3-3
NCC 2130 Main Menu Commands
The Configuration Menu
In the Main Menu shown in
, the element [I] is selected.
The letter I is defined in the Key as an IDCSU. In the case of a card
in slot 1 of shelf 1, this would be the NCC 2130 card.
The NCC 2130 contains two completely separate functions, a
network controller and a T1 IDCSU.
The T1 CSU/DSU portion of an NCC 2130 is a TAC 2130 card. Once
an NCC 2130 is installed in a node, additional T1 IDCSU
requirements can be met by adding TAC 2130 modules.
Each node (group of shelves connected together) typically has only
one node controller card. This card is located in slot 1 of shelf 1. If
additional IDCSU cards are needed, use TAC 2130 cards instead of
adding more NCC cards.
Menu Option
Description
Instructions
S) shelf/slot
Used to navigate from module
to module within a node.
Enter the shelf number and slot number of the
desired module, use a comma delimiter (1,2).
N) near element
Selects the local node.
Used to return from a far element session.
F) far element
Selects the node at the remote
end of the T1 circuit connected
to the current module.
Functions only if ESF FDL has
continuity.
Only the CSU module connected to the T1
circuit is available. You can not navigate from
module to module within the remote node.
C) configuration
Selects the Configuration
Menu.
See
and
below.
P) performance
Selects the Performance Menu. See
of this manual.
D) diagnostics
Selects the Diagnostics Menu.
See
of this manual.
O) node
administration
Selects the Node
Administration Menu.
See
and
below.
M) monitor alarms
Toggles on/off the monitor
alarms function.
If monitor alarms is ON, alarm messages are
displayed on the Craft interface as they occur.
No alarm messages are displayed if monitor
alarms is OFF.
A) alm to net mgr
Enables or disables sending
alarms to a network
management program.
See “
in this chapter for details
on sending alarms.
Select OFF if there is no path to a network
management program.
Select ON if you are using either Access
Manager 2000 or Node Manager and this NCC
module is to send alarms to the network
manager PC.
X) log off
Exits the Main Menu.
The user is logged out.