Types Of NCC

Node Controllers

Verilink’s NCC family of Node Controllers includes the following
modules:

The NCC 2130 (documented in this manual) is a TAC 2130
IDCSU (Integrated T1 CSU/DSU) with the addition of a node
controller function. The NCC 2130, like the TAC 2130 it
contains, is a self-contained module for data purposes. The
NCC 2130 does not use any midplane data bus to exchange
timeslots with any of the Verilink DSU modules (DIU 2130, DIU
2131, DIU 2140). None of the 24 DS0 timeslots on a T1
connected to an NCC 2130 can be routed across the shelf
midplane to another module.

The NCC 2020 is a TAC 2010 T1 CSU with the addition of a
node controller function. See the

NCC 2020 User Manual

for

full details. Unlike the NCC 2130, the CSU portion of an NCC
2020 can be configured to pass T1 timeslot data to a DIU
module.

Compatible

Modules

Types of application modules which can be managed by the NCC
2130 are listed in

Table 1-1

:

Table 1-1

NCC Compatible Modules

Module

Type

Usage

TAC 2010

CSU

T1 CSU which can be used as a CSU only (CSU mode), part of a CSU/DSU

(Mux mode) or in a combination of both (Drop & Insert Mode). Can be

used with up to 24 DIU 21xx DSU modules to make a data channel bank.

DIU 2130

DSU

DSU with two synchronous serial interface ports for connection of Data

Terminal Equipment (DTE). Can be used with TAC 2010 (including the TAC

2010 portion of an NCC 2020). Uses a shelf midplane to receive/transmit

data to a CSU module.

DIU 2130/DBU

DSU

DSU with a single synchronous serial interface port and modified firmware

which uses the second port to switch the DTE data from port 1 to an

external Dial Back-Up device—which must be configured to dial on DTR.

Uses a shelf midplane to receive/transmit data to a CSU module.

DIU 2130

56K/NMS

DSU

DSU with two synchronous serial interface ports and support for routing

of individual timeslots (in the “telco cloud”) to remote sites with 56K DDS

circuits. Uses a shelf midplane to receive/transmit data to a CSU module.

DIU 2140

Sub-Rate

Data

Multiplexer,

5 port DSU

DSU with five RS-232 interface ports, each individually selectable for sync

or async data, which are multiplexed into a single timeslot (DS0) of the

associated T1 CSU. Uses a shelf midplane to receive/transmit data to a

CSU module

TAC 2130

Integrated

DSU/CSU

Standalone (for data purposes) DSU/CSU, supports a single synchronous

serial interface only. Does not use any midplane bus to transfer data to

any other module.