Configuration, Using the craft interface, Craft port terminal setup – Verilink NCC 2020 (880-503284-001) Product Manual User Manual
Page 23: Using the craft interface -1, Craft port terminal setup -1, Chapter
![background image](https://www.manualsdir.com/files/808525/content/doc023.png)
Verilink NCC 2020 User Manual
3-1
Chapter
3
Configuration
This chapter covers using the Craft interface to configure the CSU
portion of the NCC 2020 Node Controller, and use of the front
panel thumbwheel switches.
Using the Craft Interface
To access the Craft interface, connect a terminal or a computer
running a terminal program to the port labeled C
RAFT
on the front
panel of the NCC 2020 module.
Craft Port
Terminal Setup
Set your terminal parameters to:
Data Rate : 19.2 kbit/s
Word Size : 8 bits
Parity : None
Stop Bits : One
Flow Control: None
The Verilink Craft interface does not assert any control leads.
NOTE: Although the Craft interface in the NCC 2020 will adjust
(autobaud) to your terminal rate, Verilink suggests using
19.2 kbit/s to conform to the requirements of other Verilink
products.
Verilink provides one of two types of "Craft cable". Both versions of
the Craft cable have an RJ-11 modular connector at one end. The
original cable has a female DB-25 connector at the otherend and a
more recent version has a DB-9 female connector. Connect the RJ-
11 modular connector to the port labeled
CRAFT
on the front of the
NCC 2020 module.
The original Craft cable pinout is as follows:
Table 3-1 Verilink Craft Cable p/n 458-501788-008
DB-25 female
RJ-11 modular
Usage
pin 2
pin 3
Transmit Data
pin 3
pin 4
Receive Data
pin 7
pin 5
Signal Ground