Login, Csu configuration, Login -2 csu configuration -2 – Verilink NCC 2020 (880-503284-001) Product Manual User Manual
Page 16

Quick Set-Up
2-2
Verilink NCC 2020 User Manual
Login
Press E
NTER
.
The prompt
YOUR PASSWORD?
YOUR PASSWORD?
YOUR PASSWORD?
YOUR PASSWORD? is displayed.
Initially there is no password, press E
NTER
.
The NCC 2020 Main Menu is displayed:
NOTE: The prompt line and menu names will refer to the NCC 2020
as a TAC 2010. This is because an NCC 2020 is a TAC 2010
T1 CSU to which the Craft interface and node controller
functions have been added.
Figure 2-2 NCC 2020 Main Menu
CSU
Configuration
When installing an NCC 2020 or TAC 2010 module which is to be
used with any type of DIU 21xx module, always configure the CSU
module before configuring anything on the DIU 21xx module. When
the DIU 21xx is configured, it is connected logically to a CSU. At
that instant the DIU gets information from the CSU as to which data
bus in the shelf midplane to use. If the CSU has not been
configured yet, the DIU 21xx will not get a correct bus assignment.
This is why the CSU should be configured first.
Type “C” and press E
NTER
. The Configuration Menu is presented.
-- VERILINK NCC NODE CONTROLLER at[1,1]: FW Rev 4.75 --
-- VERILINK NCC NODE CONTROLLER at[1,1]: FW Rev 4.75 --
-- VERILINK NCC NODE CONTROLLER at[1,1]: FW Rev 4.75 --
-- VERILINK NCC NODE CONTROLLER at[1,1]: FW Rev 4.75 --
SITE NAME:
SITE NAME:
SITE NAME:
SITE NAME:
NODE ID: 0
NODE ID: 0
NODE ID: 0
NODE ID: 0
<- SLOT ->
<- SLOT ->
<- SLOT ->
<- SLOT ->
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
1 DL [C] D
1 DL [C] D
1 DL [C] D
1 DL [C] D
2
2
2
2
3
3
3
3
4
4
4
4
KEY: C=CSU, D=DIU, F=DIU/DDS, B=DIU/DBU, R = SRD, I=IDCSU, T=TU, S=SMDS, V=VCU
KEY: C=CSU, D=DIU, F=DIU/DDS, B=DIU/DBU, R = SRD, I=IDCSU, T=TU, S=SMDS, V=VCU
KEY: C=CSU, D=DIU, F=DIU/DDS, B=DIU/DBU, R = SRD, I=IDCSU, T=TU, S=SMDS, V=VCU
KEY: C=CSU, D=DIU, F=DIU/DDS, B=DIU/DBU, R = SRD, I=IDCSU, T=TU, S=SMDS, V=VCU
S) shelf/slot D) diagnostics
S) shelf/slot D) diagnostics
S) shelf/slot D) diagnostics
S) shelf/slot D) diagnostics
N) near element O) node administration
N) near element O) node administration
N) near element O) node administration
N) near element O) node administration
F) far element M) monitor alarms (OFF)
F) far element M) monitor alarms (OFF)
F) far element M) monitor alarms (OFF)
F) far element M) monitor alarms (OFF)
C) configuration A) alm to net mgr (OFF)
C) configuration A) alm to net mgr (OFF)
C) configuration A) alm to net mgr (OFF)
C) configuration A) alm to net mgr (OFF)
P) performance X) system log off
P) performance X) system log off
P) performance X) system log off
P) performance X) system log off
[1,1] NEAR TAC 2010 >
[1,1] NEAR TAC 2010 >
[1,1] NEAR TAC 2010 >
[1,1] NEAR TAC 2010 >