Tri Tool 620SB Clamshell Hydraulic User Manual
Page 42
![background image](https://www.manualsdir.com/files/808034/content/doc042.png)
42
TRI TOOL INC.
92-0282 : Rev. 131230
Problem:
The Clamshell is slipping on the pipe or tube
Probable causes:
The Clamping Pads are not in full contact with the pipe or tube.
The clamping pressure is too light.
Scale and/or other foreign material is present on the pipe or tube.
Weld seams, swelling, or bumps under the Clamping Pads are preventing
full contact.
Dull Tool Bits are causing extra force in the axial and/or radial direction.
The pipe or tube wall is too thin which allows the tube wall to flex and the
machine to move.
Problem:
The tool bit will not reach the work
Probable causes:
Incorrect tool blocks are installed for the size of the pipe or tube being
worked on.
Incorrect tool bit is installed.
Problem:
The hydraulic motor will not start
Probable causes:
The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.