beautypg.com

Tri Tool 620SB Clamshell Hydraulic User Manual

Page 27

background image

27

Model 620SB Low Profile Clamshell, Hyd.

92-0282 : Rev. 131230

CAUTION:

Tool Bit is Too Shallow

Do not move Tool Bit A.

If the cut of Tool Bits B and C is too shallow for a blend with Tool Bits D and E as

shown in picture, then proceed on.

Go ahead to “If too deep a cut has been made….”.

Retract Tool Bits D and E without changing the position of Tool Bit A.

Tighten the Set Screws holding Tool Bits D and E.

Go back to “Engage the feed by pushing the Tripper Shaft in”.

If too deep a cut has been made by Tool Bits B and C as shown, then proceed to

“Loosen the Set Screws….”

Tool Bit is Too Deep