Sfp generated traps, Warnings, Vx/hdx/mx router snmp traps – Thinklogical Router SNMP Traps User Manual
Page 2

Vx/Hdx/Mx Router SNMP Traps
SFP Generated Traps
Warnings
•
High Temperature Warning
Begin and Clear
A SFP module has the ability to monitor and alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 7 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).
This bit is set when the internal temperature of the SFP exceeds the high temperature warning
level. The SFP temperature is stored at bytes 96 & 97 of the SFP diagnostic register table.
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighTempWarning
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
•
Low Temperature Warning
Begin and Clear
A SFP module has the ability to monitor and alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 6 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).
This bit is set when the internal temperature of the SFP falls below the low temperature warning
level. The SFP temperature is stored at bytes 96 & 97 of the SFP diagnostic register table.
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowTempWarning
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
•
High Vcc Warning
Begin and Clear
A SFP module has the ability to monitor and alarm on a high or low Vcc voltage reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 5 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).
This bit is set when the internal supply voltage to the SFP exceeds the high voltage warning
level. The SFP voltage is stored at bytes 98 & 99 of the SFP diagnostic register table.
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighVccWarning
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
Mar 19, 2014
V4.2-5
1/13