1 pulse output configuration, 2 units, 3 pulses – Tecfluid MX4 For FLOMAT Series User Manual
Page 39: 4 duty cicle
![background image](https://www.manualsdir.com/files/807348/content/doc039.png)
39
If “Unidirectional” is chosen, the output will give pulses proportional to flow rate when the
flow rate is positive, and will not give them when the flow rate is negative.
If “Bidirectional” is chosen, the output will give pulses proportional to flow rate in both flow
directions.
7.5.2.2 Units
First volume units for which we want to get a number of pulses are selected.
7.5.2.3 Pulses
Then the pulses per unit of volume that we will obtain at the output are selected .
7.5.2.4 Duty Cycle
With the duty cycle width or percentage of time the pulse will be active during each cycle
can be determined
Active pulse is when the NPN transistor at the output (see 2.2.5) is ON.
7.5.2.1 Pulse output configuration
It allows to choose between unidirectional and bidirectional.
7
CONVERTER PROGRAMMING
- AMD For 2000 Series (4 pages)
- AMO For 6000 Series (4 pages)
- AMR For 6000 Series (4 pages)
- AMM For 6000 Series (8 pages)
- LT-AMD (4 pages)
- TR420 (8 pages)
- AD Series (4 pages)
- TH6 For M21 Series (12 pages)
- TH5 For DP Series (12 pages)
- AMM For DP Series (8 pages)
- FLOMAT Series (12 pages)
- FLOMID-MX (20 pages)
- XT5D (24 pages)
- MX4H (24 pages)
- FLOMID Series (8 pages)
- LC Series (4 pages)
- LC40 Series (8 pages)
- LC-40 ADF (4 pages)
- MX4 For FLOMID Series (64 pages)
- LD61 (8 pages)
- LD60 (8 pages)
- LD61N (8 pages)
- LD61R (12 pages)
- LP Series (12 pages)
- TR2420 (12 pages)
- LT-APR (4 pages)
- LTL-AMM (4 pages)
- LTL-APR (4 pages)
- LTL-ADF (4 pages)
- VH35 AISI-316 (4 pages)
- MC01 4-20 mA input (12 pages)
- LU Series (28 pages)
- MT-02 (9 pages)
- MT03L (32 pages)
- MT03F (40 pages)
- CH420L (8 pages)
- CH420R (12 pages)
- CH420P (12 pages)
- CIP (4 pages)
- CIP II (8 pages)
- DFD-2 E (8 pages)
- APTM44 (6 pages)
- CI-420 (8 pages)