Setting mode (3), Clock output frequency setting display: wout – Teac D-07x User Manual
Page 16
16
Clock output frequency setting
Display: WOUT>***
Sets the frequency of the signal output from the CLOCK OUT connector.
Use when synchronizing playback of a device that has a clock sync
input connector, such as an Esoteric P-05, with the D-07X.
o
This setting only appears when CLK is set to OUT, IN or DMCK.
o
A different setting can be made for each input.
The items that can be selected depend on the CLK setting.
When the CLK setting is OUT
44.1kHz
z
88.2kHz
z
176.4kHz
z
22.5792MHz
z
48kHz
z
96kHz
z
192kHz
z
24.576MHz
z
100kHz
o
When set to 44.1, 88.2 or 176.4 kHz or 22.5792 MHz, the audio
signals that can be input are 44.1, 88.2 and 176.4 kHz and DSD.
o
When set to 48, 96 or 192 kHz or 24.576 MHz, the audio signals
that can be input are 48, 96 and 192 kHz.
o
When set to 100 kHz (universal clock), the audio signals that can
be input are 44.1, 88.2 and 176.4 kHz and DSD.
Use when connected to an Esoteric device, such as a UX-1 or
UX-3, that supports universal clock.
When the CLK setting is IN
OFF
z
THRU
z
1Fs
z
2Fs
z
4Fs
z
MCK
z
100kHz
When the CLK setting is DMCK
OFF
z
THRU
z
1Fs
z
2Fs
z
4Fs
z
MCK
o
The source device must receive clock input from a clock generator
and be synchronized.
OFF
No clock signal is output.
THRU
The clock signal input through the CLOCK IN connector is output
without changing the frequency.
1Fs, 2Fs, 4Fs
A clock signal is output that is 1, 2 or 4 times the base sampling
frequency of the input clock signal, which must be either 44.1 kHz
or 48 kHz.
MCK
A master clock (MCK) signal is output that is 512 times the base
sampling frequency of the input clock signal, which must be either
44.1 kHz or 48 kHz.
100k
Universal clock (100 kHz) is output.
Setting mode (3)