From Controlling device
Return from SX-1
Command
CMD 1 CMD 2 DATA
NAME
CMD1 CMD 2 DATA
TIMER-1 PRESET
44
00
*5
ACK
10
01
*1
EDIT PRESET
41
30
*11
ACK
10
01
*6
TAPE/AUTO SELECT
41
32
XX
ACK
10
01
*1
SERVO REF SELECT
41
33
XX
ACK
10
01
*1
HEAD SELECT
41
34
XX
ACK
10
01
*1
COLOR FRAME SELECT
41
35
XX
ACK
10
01
*1
TIMER MODE
41
36
XX
ACK
10
01
*1
EDIT FIELD SELECT
41
3A
*16
ACK
10
01
CURRENT TIME SENSE
61
0C
*15
TIMER-1 DATA
74
00
TIMER-2 DATA
74
01
LTC TIME DATA
74
04
LTC TIME&UB DATA
78
04
LTC UB DATA
74
05
VITC TIME DATA
74
06
VITC TIME&UB DATA
78
06
VITC UB DATA
74
07
LTC INTERPOLATED
74
14
TIME DATA
LTC INTERPOLATED
78
14
TIME&UB DATA
VITC HOLD TIME DAT 74
16
VITC HOLD TIME &
78
16
UB DATA
STATUS SENSE
61
20
STATUS DATA
7x
20
*13
EDIT PRESET SENSE
61
30
EDIT PRESET DATA
7x
30
*14
TIMER MODE SENSE
60
36
TIMER MODE
71
36
00
Unsuported Commands
XX
YY
NAK
11
12
*12
Notes:
*1 Command is acknowledged, but no action is taken.
*2 The SX-1 can selectively reply to this command, set in the LCD Preferences screen,
TRANSPORT page.
F01A TASCAM HDR Series (Default)
6003 Sony 3324S
101C Sony BVU950
This reply data is also affected by the Frame Rate setting of the currently loaded project.