Super Systems 9210 Series User Manual
Page 6

M4557 - Model 9210 Nitriding Controller
SSi Manual SERIES 9210-M4557-Nitriding
Page 6 of 6
About This Manual
This instrument is designed for Nitriding control and configured per individual customer requirements. This
manual covers the operation of the Model 9210 Nitriding Controller, the Nitriding Control System and the
Gas Flow Panel.
Controller Description
The Model 9210-Nitriding instrument is a multi-loop Proportional Integral Derivative (PID) controller that
can be custom configured to control up to three Nitriding process loops. General features of this product
include:
The Model 9210 is powered by 24 VDC,
NOT
LINE Voltage. Please be careful when connecting power to
this controller. Connecting anything other then 24 VDC will cause serious damage.
Approximate Box Dimensions
2.75" x 4" x 4.5"
Power Requirements
24VDC, 4 Watts
Digital Output Rating
300VAC / 1 AMP
Analog Output Load Rating
1000 Ohms (Total)
Controller Enclosure Rating
IP10 – hand protected
Number of RS232 Ports
Two (2)
Number of Ethernet Ports
One (1)
Number of RS485 Host Ports
One (1)
Number of RS485 Slave Ports
Two (2)
Number of Internal Relays
Eight (8)
Number of Analog Inputs
Three (3)
Number of Analog Outputs
Two (2)
Number of Digital Inputs
Four (4)
Number of Control Loops
Three (3)
The control enclosure is powered by 120 VAC, Single Phase, 60 Hz (Line Power). Line voltage for the
isolation relays comes from the same source.
!