Super Systems 7EK 31080 User Manual
Page 29
Appendix A.1
APPENDIX A
DEFAULT PARAMETERS
DEFAULT RUN TIME PARAMETERS
PARAMETER
DEFAULT VALUE
SP
= Initial scale value
SnRT
= Disable
n.SRt
= OFF
SP2
= Initial scale value
nnn
= OFF
AL1
= Initial scale value for process alarm
0 for deviation or band alarm
HSA1
= 0.1 %
AL2
= Initial scale value for process alarm
0 for deviation or band alarm
HSA2
= 0.1 %
AL3
= Initial scale value for process alarm
= 0 for deviation or band alarm
HSA3
= 0.1 %
PB
= 4.0 %
HyS
= 0.5 %
ti
= 4.00 (4 minutes)
td
= 1.00 (1 minute)
IP
= 30 % if one control output is
configured
= 0 if two control outputs are
configured
Cy1
= 15 seconds for relay output
= 4 seconds for SSR output
Cy2
= 10 seconds for P8 = AIr
= 4 seconds for P8 = OIL
= 2 seconds for P8 = H2O
rC
= 1.00 for P8 = AIr
= 0.80 for P8 = OIL
= 0.40 for P8 = H2O
OLAP
= 0
rL
= Initial scale value
rH
= Full scale value
Grd 1
= Infinite (step transfer)
Grd 2
= Infinite (step transfer)
OLH
= 100 %
tOL
= Infinite
Hbd
= 50 % of the full scale value
SCA
= 100% of the full scale value
rnP
= Infinite
31080-A-00.p65
3/24/00, 11:58 AM
1