beautypg.com

1 location of smt391 test points, 8 power supply, Power supply – Sundance SMT791 User Manual

Page 21

background image

7.1 Location of SMT391 Test Points

The following figure shows the location of the voltage test points on the SMT391.

Figure 14: Voltage Test Point Locations.

8 Power Supply

The following voltages are required by the SMT391 and must be supplied over the
daughter card power connector.

Voltage

Current
Required

D+3V3_IN 2.0

A

D+5V0_IN 500

mA

D+12V0_IN 250

mA

D-12V0_IN 250

mA

DGND

Figure 15: SMT391 Power Supply Voltages.


The following table lists the internal SMT391 voltages that are derived from the
voltages that are provided over the daughter card power connector.

Voltage

Description

D+3V3

Derived from D+3V3_IN

D+2V25

Derived from D+3V3 on
SMT391

User Manual SMT791

Page 21 of 21

Last Edited: 12/10/2010 09:52:00