beautypg.com

Opep-33-a4q1ri – Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI User Manual

Page 11

background image

OPEP-33-A4Q1RI

DELTA ELECTRONICS, INC.

11 Revision:

S3

12/20/2007

www.deltaww.com

Digital Diagnostic Monitoring Interface (2-Wire Address A2h)

Alarm and Warning Thresholds (2 Wire Address A2h)

Address

# Bytes

Name of Field

HEX

Real Value

Unit

00-01 2

Temp

High

Alarm

64 00

100℃

ºC

02-03 2

Temp

Low

Alarm

DD 00

-35℃

ºC

04-05

2

Temp High Warning

5A 00

90℃

ºC

06-07

2

Temp Low Warning

E7 00

-25℃

ºC

08-09

2

Voltage High Alarm

94 70

3.8

V

10-11 2

Voltage

Low

Alarm

6D

60

2.8

V

12-13 2

Voltage

High

Warning

87

8C 3.47

V

14-15 2

Voltage

Low

Warning

7A

44 3.13

V

16-17 2

Bias

High

Alarm

4E

20

40

mA

18-19

2

Bias Low Alarm

01 F4

1

mA

20-21

2

Bias High Warning

3A 98

30

mA

22-23

2

Bias Low Warning

01 F4

1

mA

24-25 2

TX

Power

High

Alarm

26-27 2

TX

Power

Low

Alarm

28-29

2

TX Power High Warning

30-31

2

TX Power Low Warning

No implemented for Burst Mode.

32-33

2

RX Power High Alarm

27 10

0

dBm

34-35 2

RX

Power

Low

Alarm

00

0D

-29

dBm

36-37

2

RX Power High Warning

13 94

-3

dBm

38-39

2

RX Power Low Warning

00 19

-26

dBm

40-55 16

Reserved



Calibration Constants (2 Wire Address A2h)

Address # Bytes

Name of Field

HEX

Description

56-59

4

Rx_PWR (4)

00 00 00 00

Set to zero for “internally calibrated” devices.

60-63

4

Rx_PWR (3)

00 00 00 00

Set to zero for “internally calibrated” devices.

64-67

4

Rx_PWR (2)

00 00 00 00

Set to zero for “internally calibrated” devices.

68-71

4

Rx_PWR (1)

3F 80 00 00

Set to 1 for “internally calibrated” devices.

72-75

4

Rx_PWR (0)

00 00 00 00

Set to zero for “internally calibrated” devices.

76-77

2

Tx_I (Slope)

01 00

Set to 1 for “internally calibrated” devices.

78-79

2

Tx_I (Offset)

00 00

Set to zero for “internally calibrated” devices.

80-81

2

Tx_PWR (Slope)

01 00

Set to 1 for “internally calibrated” devices.

82-83

2

Tx_PWR (Offset)

00 00

Set to zero for “internally calibrated” devices.

84-85

2

T (Slope)

01 00

Set to 1 for “internally calibrated” devices.

86-87

2

T (Offset)

00 00

Set to zero for “internally calibrated” devices.

88-89

2

V (Slope)

01 00

Set to 1 for “internally calibrated” devices.

90-91

2

V (Offset)

00 00

Set to zero for “internally calibrated” devices.

92-94 3

Reserved

00

00

00

Reserved

95

1

Checksum

XX

Checksum of bytes 0 – 94.