beautypg.com

Space Ray ETS Series User Manual

Page 37

background image

Form 43343300

-36-

May 2013

C.

C.

C.

C.

LOW

LOW

LOW

LOW VOLTAGE (

VOLTAGE (

VOLTAGE (

VOLTAGE (24

24

24

24V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS –

– SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT


42874990 Rev. C 1/2012

NOTES:

1. If any of the original wire

as supplied with the

appliance must be replaced,

it must be replaced with

wiring material having a

temperature rating of least

105 deg. C. (18 AWG-

UL/CSA 600V Type TEW.

2. When connecting the

supply circuit to the heater,

wiring material having a

minimum size of 14 AWG

and a temperature rating of

at least 90 deg. C shall be

used.

BL

BL

BK

BK

BK

BK

BK

W

BK

W

GAS VALVE

AIR SWITCH

TRANSFORMER 120V

PRIMARY 24V

SECONDARY

AMBER

GREEN

RED

HIGH VOLTAGE

CABLE

ELECTRODE

GAP 3/16”

CONTINUE TO

ADDITIONAL

HEATERS

NEUTRAL

120V

GROUND

L1

L2

TERMINAL

BLOCK

FACTORY WIRING

FIELD WIRING

CONTROL CABINET

MONITORING LIGHTS

FUSE 2A

JUNCTION BOX

SJO CABLE

W

R

BK

LOW VOLTAGE

THERMOSTAT (24V)

FIELD INSTALLED

RELAY KIT PART

NO. 43274010

R

W

3

4

5

1

DRAFT

INDUCER

MOTOR

BK

BK

BK

W

W

R

R

BK W

G

IGNITION MODULE

GND

(BURNER)

25V

Bloc d'allumage

VALVE

VALVE

Order 24V Relay Kit (Part No. 432740

Order 24V Relay Kit (Part No. 432740

Order 24V Relay Kit (Part No. 432740

Order 24V Relay Kit (Part No. 4327401

1

1

10) for Low Voltage (24V) thermostat connection.

0) for Low Voltage (24V) thermostat connection.

0) for Low Voltage (24V) thermostat connection.

0) for Low Voltage (24V) thermostat connection.

NOTES:

NOTES:

NOTES:

NOTES:

1.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring

material having a temperature rating of at least 105ºC. (18 Ga. CSA 600V Type TEW)

2.

When connecting the supply circuit to the heater, wiring material having a minimum size of 14 AWG and a

temperature rating of at least 90ºC shall be used.

3.

A replaceable 2-amp fuse (1-1/4” long) is fitted to the terminal block located inside the junction box

assembly.

D.

D.

D.

D.

LLLLOW

OW

OW

OW VOLTAGE (

VOLTAGE (

VOLTAGE (

VOLTAGE (24

24

24

24V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS –

– MULTIPLE HEATERS

MULTIPLE HEATERS

MULTIPLE HEATERS

MULTIPLE HEATERS PER THERMOSTAT

PER THERMOSTAT

PER THERMOSTAT

PER THERMOSTAT


Ground
Neutral

Hot (120VAC)

Fused

Disconnect

Switch

Service

Switch

Heater 1

Continue To

Additional

Heaters

Service

Switch

Heater 2

Low Voltage

Thermostat (24V)

coil

C

R

G

NO

Fan Center Relay Part No. 30169000

Contact Rating: 120V, 40VA, 12A

(maximum of 6 heaters per relay)

This manual is related to the following products: