Programming the 844 sprayer control system – Smithco Spray Star 1607P (1999) Operator Manual User Manual

Page 19

background image

17

Operation

PROGRAMMING THE 844 SPRAYER CONTROL SYSTEM

(

CONTINUED

)

NOZZLE SPACING

Default = 20

1. While in the Nozzle Spacing step, the

symbol will be flashing at the top of the console display.

2. Nozzle spacing should be recorded in inches.

3. If the default value is correct, depress the

key to accept the value.

4. If the nozzle spacing is different than that shown as a default, then add or reduce this number by using

the

or

keys to record the new value. Depressing the

and

keys simultaneously will

clear the value to zero.

5. When the correct value has been entered, depress the

key to accept the value and advance to the

next step.

6. When broadcast spraying, enter the nozzle spacing in the display.

7. If banding, enter the band width as your spacing.

8. If directed spraying, enter the row spacing divided by the number of nozzles per row as your spacing.

All Application rate readings (GPA, G/1000 ft²) and area readings are expressed in

treated acres.

NUMBER OF SPRAY TIPS PER BOOM SECTION

Default = 6

1. While in the Tips Per Boom Section step, the

symbol will be flashing at the top of the console

display. The console will also display “SEC 1” at the left and a number (6) at the right of the display. The
SEC 1” refers to boom section #1 on your sprayer. The number at the right is to be adjusted to match
the number of tips you have on boom section 1.

2. The default value of “6” will appear for all booms sections. The next 3 or 5 programming steps are

Number of Spray Tips Per Boom Section steps. These steps correspond with the 3 or 5 boom switches
on the lower portion of the console, depending on the 844 console you purchased. The section you are
programming can be identified by looking at the SEC # at the left of the display.

3. You must program the correct number of spray tips for each boom section on your sprayer. Use the

or

keys to produce the correct value. Depressing the

and

keys simultaneously will clear the

value to zero.

4. Advance to the next step by depressing the

key. This must be done for all Number of Spray Tips Per

Boom Section steps.

5. Any individual boom switches not being used must be programmed to a “0” value. When you have

programmed and validated the last Number of Spray Tips Per Boom Section step, advance to the next

program step by depressing the

key.