Sensoray 526 User Manual
Page 22
22
ADC Control Register
0x06
Bits
Type
Default
Description
[15]
WO
0
Input multiplexor settling delay:
0 – no delay;
1 – 12
µ
s delay.
[14:5]
WO
0x000
ADC conversion control. A 1 enables conversion of the
corresponding channel:
[14] – enable conversion on reference 1 (0 V);
[13] – enable conversion on reference 0 (+10 V);
[12] – enable conversion of channel 7;
[11] – enable conversion of channel 6;
[10] – enable conversion of channel 5;
[9] – enable conversion of channel 4;
[8] – enable conversion of channel 3;
[7] – enable conversion of channel 2;
[6] – enable conversion of channel 1;
[5] – enable conversion of channel 0.
[4:1]
WO
0000
ADC read channel select:
0000 - channel 0;
0001 - channel 1;
0010 - channel 2;
0011 - channel 3;
0100 - channel 4;
0101 - channel 5;
0110 - channel 6;
0111 - channel 7;
1000 - reference 0 (+10 V);
1001 - reference 1 (0 V).
[0]
WO
0
ADC start. Writing a 1 to this bit starts conversion on channels
selected with bits [14:5] (Note 1). Bit [2] of the Interrupt
Status register is set to 1 when upload is complete.
Notes:
1.
Selection of channels and ADC start can be performed in one access to the ADC Control
register.
DAC/ADC Data Register
0x08
Bits
Type
Default
Description
[15:0]
RW
0x0000
Write operation: data to be written to DAC preload register for
the channel selected in DAC control register.
Read operation: conversion result from ADC channel selected in
ADC control register.