Scotsman F1222L Service Manual User Manual
Page 7
N0922L, N1322L, F1222L, F1522L
Remote Low Side Service Manual Includes Prodigy Plus
December 2014
Page 7
Water
The water supply for ice making must be cold, potable
water. There is a single 3/8” male flare potable water
connection on the back panel.
Backflow
The design of the float valve and reservoir prevents
potable water backflow by means of a 1" air gap
between the reservoir's maximum water level and the
float valve water inlet orifice.
Drain
There is one ¾” FPT condensate drain fitting at the
back of the cabinet.
Tubing
Connect the potable water
supply to the potable water
fitting, 3/8” OD copper tubing or
the equivalent is recommended.
Connect the drain tube to the
condensate drain fitting. Vent this
drain tube.
Do not Tee ice machine drains
into the drain tube from the ice
storage bin or dispenser. Back
ups could contaminate and
/ or melt the ice in the bin or
dispenser.
Follow all local and national
codes for tubing, traps and air
gaps.
Potable Water Inlet
Condensate Drain