beautypg.com

Scotsman F1222L Service Manual User Manual

Page 17

background image

N0922L, N1322L, F1222L, F1522L

Remote Low Side Service Manual Includes Prodigy Plus

December 2014

Page 17

Electrical Sequence with Condensing Unit

Pushing and releasing the On button starts the

machine. The sequence of operation begins with

water. Water must be sensed or the controller will

not start the ice making process. If there is no water,

a 3 will show it the code display. If there is water,

and there is nothing blocking the infrared beam of

the ice sensors, the controller will start the machine.

A flashing F will show in the code display while the

auger drive motor starts up. When it has started,

the liquid line valve will open and the flashing F will

change to a continuous F.

An open liquid line valve allows refrigerant to flow

from the condensing unit into the evaporator and

suction line. That raises the suction pressure at the

condensing unit, causing the low pressure switch to

close, starting the compressor.

Ice making continues until the ice level control senses

a full bin, at that time the compressor is shut off, and

the auger motor continues to operate for a short time

to clear the evaporator of any left over ice. A b will

show in the code display.