Page 14
Component Indicator Lights
The controller has six lights to indicate component
operation:
Bin Eyes Blocked
• This light is ON when the photo-electric ice
sensors have been blocked by ice.
Water Present
• This light is ON when the water sensor has water
touching it.
Comp
• May light but is not used on this model.
Water Dispense
• Not used on this model, not present on Prodigy
Plus
Auger
• This light is ON when the auger motor is
operating.
Ice Dispense
• Not used on this model, not present on Prodigy
Plus
Control Button Use
Recall diagnostic code:
• Hold off button in for 3 seconds. Release.
• Press and release the Clean button to cycle
through each of the last 10 error codes from most
recent to oldest.
Clear diagnostic code:
• Hold Clean and Off buttons in for 3 seconds to
clear all prior codes.
Reset control:
• Depress and release Off, then depress and
release On
Start Test Mode:
• Hold Off button in for 3 seconds. Release.
• Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
• Hold On button in for 3 seconds, keep holding
then press and release Off twice.