Component Indicator Lights

The controller has six lights to indicate component

operation:

Bin Eyes Blocked
• This light is ON when the photo-electric ice

sensors have been blocked by ice.

Water Present
• This light is ON when the water sensor has water

touching it.

Comp
• May light but is not used on this model.

Water Dispense

• Not used on this model, not present on Prodigy

Plus

Auger
• This light is ON when the auger motor is

operating.

Ice Dispense

• Not used on this model, not present on Prodigy

Plus

Control Button Use

Recall diagnostic code:
• Hold off button in for 3 seconds. Release.

• Press and release the Clean button to cycle

through each of the last 10 error codes from most

recent to oldest.

Clear diagnostic code:
• Hold Clean and Off buttons in for 3 seconds to

clear all prior codes.

Reset control:
• Depress and release Off, then depress and

release On

Start Test Mode:
• Hold Off button in for 3 seconds. Release.

• Hold Clean button in for 3 seconds. Release.

Lock / Unlock control:
• Hold On button in for 3 seconds, keep holding

then press and release Off twice.